Failures of individual components are the norm: disks, servers and network links break regularly. The problem is that one of the components may have no duplicate, and when it fails it takes down the whole system or its critical part. Finding such places and removing them is the first step in designing reliable infrastructure.
How single points of failure are found
The system is traced mentally along the chain from the user to the data, and at each step the question is: what breaks if this component fails right now, and who would take its place. A dependency without a working duplicate in another failure domain is a single point of failure. In the contingency planning guide, NIST advises starting with critical systems: failure points are sought for the systems and processes identified in the business impact analysis.
| Location | Example | How it is covered |
|---|---|---|
| Traffic entry | a single provider link or a single edge router | a backup link, a pair of routers |
| Load balancing | a single load balancer in front of all servers | a pair of load balancers in an active-passive configuration |
| Data | a single database server with no replicas | replication and automatic failover |
| Power and site | a single power feed, a single data centre | a second power feed, distribution across availability zones |
| Processes | one machine builds the releases, only one person has production access | build automation, documentation, shared access |
How they are eliminated
Components are duplicated — so that the copies do not share a fate: in different racks, availability zones or regions, from different vendors, sometimes even on different technologies — diversity keeps a single type of failure from striking all copies at once. Redundancy is expensive, so NIST recommends adding it to critical components and relying on the recovery plan for the rest.
Duplicates do not help while their shared mechanism remains a new point of failure: a pair of database servers behind a single load balancer still runs into it. In clusters with quorum, the number of tolerated failures is counted explicitly: for example, the etcd store accepts writes only if more than half of the nodes agree — (n/2)+1:
| Nodes in the cluster | Failures survived |
|---|---|
| 1 | 0 |
| 2 | 0 |
| 3 | 1 |
| 4 | 1 |
| 5 | 2 |
| 7 | 3 |
Testing does not end with the diagram: a failure is induced on purpose — a node, a link or a zone is switched off — and what actually happens is observed. This is how hidden points of failure come to light, such as a standby that nobody has checked for years and that will not come up in a real incident.
Sources
the term is written from these pages- NIST SP 800-34 Rev. 1 — Contingency Planning Guide for Federal Information Systemsnvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800-34r1.pdf(opens in a new tab)