Infrastructure and cloud architecture

Infrastructure and cloud architecture — design of data centers and the cloud to meet business requirements. The reference covers: high availability, DR, networking, IaC and TCO.

checked 7 Nov · next check 14 Nov · 84 min read

Sections
14
Reading
84 min
Languages
RU · UZ · EN
Written from
docs.aws.amazon.com/wellarchitected/latest/framework/welcome.html

Check status of the reference

Verified 7 Nov · next check 14 Nov

The sections were compared with the release notes, the check found nothing, and all source links respond.

  1. Verified
  2. Scheduled check

What is infrastructure architecture

Infrastructure architecture is a set of decisions about facility, network, compute, storage and operations: which machines run which workloads, where and how, and what it all costs. Decisions are not taken out of habit — they are derived from requirements: workload volume, availability, recovery, budget and regulatory rules.

Well-Architected Framework terms: a component is code, configuration and resources that together fulfil one requirement; a workload is a set of components that together deliver business value; architecture is how these components work together. At Azure, a workload also includes data and the supporting infrastructure, and it is designed against functional and non-functional requirements.

Decisions are laid out in layers: from the ground — the facility — up to applications. Each layer is chosen to match the workload’s requirements, while observability and security are not confined to a separate “floor” — they cut across all layers and are designed together with them.

Each layer is chosen to match the requirements; cross-cutting layers are not added after launch.
LayerWhat is decidedExample decision
FacilityIn which country and building the machines standOwn data centre, a rack in colocation, a cloud region
NetworkHow nodes find each other and how traffic leaves for the outsideSegments, load balancer, backup channel
ComputeWhat the code runs onServers, virtual machines, containers
StorageWhere data lives and how durable it isBlock volumes, file share, object storage
PlatformWhat automates the routine on top of the machinesKubernetes, managed database, the team’s internal platform
Observability (cross-cutting)How problems are learned about before users noticeMetrics, logs, traces, on-call duty
Security (cross-cutting)Who and what is allowed near the systemNetwork segmentation, secrets, role-based access

What the architecture is derived from

Requirements fall into functional — what the system does — and non-functional — how it does it: load and growth, availability expressed as a service level objective (SLO), the recovery time objective (RTO) and recovery point objective (RPO), data volume and classification, budget, and regulatory requirements — for example, on personal data. Without numbers the architecture cannot be verified: there is no way to say whether it will sustain peak load or whether recovery will fit into the deadline.

HLD and LLD: two levels of design

A project is described at two levels of detail. The high-level design (HLD) answers the “what and where” questions, the low-level design (LLD) — “how exactly”.

DocumentWhat it containsExample
HLD, high-level designSites and zones, network segments, traffic flows, the redundancy and disaster recovery scheme“The application runs in two zones, the database — with a replica in the second”
LLD, low-level designAddress plan and VLANs, server models, volume sizes, firewall rules, resource names“VLAN 30 — 10.20.30.0/24, web nodes”

The architecture is designed by an infrastructure architect, DevOps engineers and SREs. Classically, a separate architecture team handles this, with the roles of Technical Architect (infrastructure), Solutions Architect, Data Architect, Networking Architect and Security Architect. AWS chose a different path: every product team has the ability to design, and a community of senior engineers helps it keep the bar high. DevOps is a practice in which development and operations share responsibility for the system in production.

A formal design is not always needed. A single virtual machine for an internal service gets by with a checklist (see the section “Infrastructure design checklist”). Several environments, a service level agreement (SLA) to customers, personal data or a regulator — reasons to sit down to HLD and LLD.

How it differs from other fields

FieldWhat is decided thereWhat is decided here
Software architectureApplication styles and modularity, C4 diagrams, ADRsWhere this code runs: machines, network, storage
Security architectureThreat model, Zero Trust, IAM as a wholeSegmentation, DMZ and secrets as part of the design
AI infrastructureGPU clusters, NVLink and InfiniBand, power and coolingShared layers — without the GPU specifics
Tool references: Terraform, Kubernetes, AnsibleHow to use a particular toolWhich decisions the tool embodies
The “TCP/IP and DNS” referenceMechanisms: addressing, routing, DNSDesign decisions: segmentation, load balancing, CDN

What to know in advance

  • The “TCP/IP and DNS” reference: addresses, ports and name resolution — the network layer stands on them.
  • The “Linux” reference: processes, permissions, disks and services — the base for any machine.
  • The “Virtualisation” reference: how a single server is turned into several isolated machines.
  • The “Docker” reference: containers, out of which the compute layer is most often assembled.

Section sources

the section is written from these pages

Infrastructure design checklist

The infrastructure design checklist is 24 questions to answer before you start designing: load, availability, data, the regulator, budget, the team and operations. Run through it before the HLD of a new project, a move to the cloud or to another data centre, and the renewal of the contract with a provider.

An HLD (high-level design) rests on answers, not on guesses: without a budget limit and recovery targets, choosing the facility and compute is impossible. An item counts as closed when the answer is written down as a number or a name and confirmed by the owner of the system; an answer of “roughly” leaves the item open. The groups below follow the Design review checklist for Reliability (RE:01–RE:10) and the Design review checklist for Cost Optimization (CO:01–CO:14) of the Microsoft Azure Well-Architected Framework.

Keep the answers in a file in the repository next to the code: the requirements reach review, and the history of changes is preserved.

yamlthe requirements in requirements.yaml
# infrastructure requirements of the projectworkload:  rps_peak: 500  users_concurrent: 20000  growth_horizon_months: 24recovery:  rto_minutes: 60  rpo_minutes: 15data:  volume_gb: 800  volume_gb_in_3_years: 5000budget:  monthly_limit_usd: 3000  overflow_approver: cto

Load and growth

  • Write down the peak and average load — requests per second and concurrent users.
  • Estimate load growth over a horizon of 12–36 months.
  • Note the seasonal peaks: sales campaigns, reporting periods, the start of the school year.

Availability and recovery

  • Set a service level objective (SLO) for every critical flow.
  • For every system that holds data, define a recovery time objective (RTO) and a recovery point objective (RPO).
  • Name the person who declares an incident and starts the recovery.
  • Write a disaster recovery (DR) plan and test it with a drill before the system goes live.

Data

  • Estimate the volume of data now and in three years’ time.
  • Give every dataset a class: personal data, payment data, trade secrets.
  • State the retention period of every class and the location of the copies: where and how often they are made.

Regulator

  • Check the current version of the personal data law (ZRU-547) on lex.uz.
  • Establish which data must be stored in Uzbekistan: biometric data, genetic data and the subscriber data of telecom operators.
  • For the remaining data, choose the legal basis for storing it abroad: a country with equivalent protection, standard contractual clauses or binding corporate rules, international standards.
  • Register the databases that must be kept in the country in the State Register of Personal Data Databases.

Budget

  • Choose a spending model: capital (CAPEX) or operating (OPEX).
  • Name the monthly spending limit and who approves going over it.
  • Include egress traffic and the secondary site in the cost model.
  • Build the cost model with a buffer for unplanned spending.

Team and support

  • Name who is on call 24/7 and what procedure they follow.
  • Match the team’s skills against the stack: Linux, Kubernetes, your chosen cloud.
  • Check the service level agreement (SLA) with the vendor: response time and the escalation path.

Operations

  • Decide on the set of environments: dev, staging, production.
  • Agree to make infrastructure changes only through infrastructure as code (IaC).
  • Choose the metrics and logs that are collected from day one.
GroupWhere it is explained
Load and growththe section “Compute: servers, VMs and containers”
Availability and recoverythe sections “Availability, SLAs and SLOs”, “Backups and disaster recovery”
Datathe section “Storage: block, file and object”
Regulatorthe personal data law on lex.uz
Budgetthe section “Cost: TCO, CAPEX, OPEX and FinOps”
Team and supportthe section “Observability and operations”
Operationsthe sections “IaC, GitOps and deployment strategies”, “Observability and operations”

The checklist does not cover the security review — it follows the threat model in the “Security architecture” reference — or load testing and server hardening: the “Load testing” and “Linux server hardening” references have checklists of their own.

Section sources

the section is written from these pages

Availability, SLAs and SLOs

Availability is the share of time when a service does its job: available time divided by total time. Planned work is not excluded from the formula: to a user who needs the service during maintenance, it is just as unavailable.

Availability is measured either by time or by requests. The time formula is available time over a period divided by the whole period. By requests — the share of successful requests over the measurement window: it comes straight from monitoring and doubles as the SLI.

SLI, SLO and SLA

Three terms describe one level of service at different levels of obligation. The indicator SLI (service level indicator) is a measurement, the objective SLO (service level objective) is the team’s internal target, and the agreement SLA (service level agreement) is a contract with the client and the consequences of missing it.

TermWhat it isExample
SLIshare of successful requests over 28 days99.95% of successful requests over 28 days
SLOtarget value of the SLI, an internal targeta target of 99.9% of successful requests over 28 days
SLAa contract with the client: a shortfall — compensationbelow 99.5% — part of the payment is refunded

An OLA (operational level agreement) is the same level-of-service agreement, but between teams inside a company, for example between operations and development. The boundary between an SLO and an SLA: if nobody pays for a shortfall, it is an SLO.

The ladder of nines

Each added nine cuts the tolerable downtime by roughly an order of magnitude. The table gives the maximum unavailability per year at which the target is still met.

AvailabilityDowntime per yearWhere it fits
99%3 days 15 hoursbatch jobs, data exports
99.9%8 hours 45 minutesinternal tools
99.95%4 hours 22 minutesan online shop, a till
99.99%52 minutesvideo delivery, live streams
99.999%about 5 minutescash machines, telecoms

Counting the chain of dependencies

Serial (hard) dependencies multiply: the availability of a chain is the product of the availability of its links. Parallel independent copies of one link count as 1 − (1 − A)ⁿ: two copies at 99.9% give 99.9999%.

Worked example: a load balancer at 99.99% → two independent application servers at 99.9% each → a database at 99.95%. Without the second server the chain gives 99.99% × 99.9% × 99.95% = 99.84% — about 14 hours of downtime a year. With the pair of servers the application gives 99.9999%, and the total rises to 99.94% — about 5.3 hours a year. The weak link is now the database: without redundancy there, further nines add nothing.

Duplicating one link lifts only that link: 99.84% → 99.94%.

Single point of failure

A single point of failure (SPOF) is a link whose failure breaks the whole service. To find one, walk the request path: for every link ask “what happens if it is switched off”. Logical links count too: DNS, a certificate, the cloud account, the only communication channel and the only person with access — frequent points of failure beyond the servers.

MTBF and MTTR

The mean time between failure (MTBF) is the average operating time before a failure. The mean time to recover (MTTR) is the time from detecting a failure to restoring the component. From them one estimates the availability of a link for which the vendor publishes no figure of its own: MTBF divided by the sum of MTBF and MTTR.

Availability grows both from rarer failures and from faster recovery. Cutting the MTTR — automatic failover, a ready runbook — is usually cheaper than buying more reliable hardware.

Active-active and active-passive

Redundancy for a whole service is arranged in two schemes. In active-active all copies serve traffic at the same time, and the failure of one is barely noticeable. In active-passive the standby waits and switches in when the primary fails.

SchemeHow it worksSwitchoverCost
active-activeall copies serve trafficalmost instantall capacity is paid for all the time
active-passivethe standby is kept hot or coldautomatic or manualthe standby is cheaper or nearly free

Switching to the standby is failover; switching back to the primary after the failure is fixed is failback, which is planned in advance.

Availability zones and regions

An availability zone is one or more data centers inside a region with independent power, cooling and network. The zones are spread a noticeable distance apart — many kilometres, though at AWS no more than 100 kilometres: latency stays low while a common failure is unlikely. Two or three zones protect against the failure of a data center, two regions — against the failure of a region. The price is the latency between zones and the cost of replicating data.

High availability in your own data center is assembled from the same techniques: two power feeds, a pair of ToR switches, a three-node cluster for the sake of quorum. In detail — in the sections “Data centers and Tier levels” and “Compute: servers, VMs and containers”.

Further reading

Balancing traffic between copies — in the section “Load balancing” of the Nginx reference; Services and Pod readiness probes — in the Kubernetes reference, the section “Services, Ingress and Gateway API”; PostgreSQL replication and its high-availability clusters — in the section “Replication and high availability” of the PostgreSQL reference; clustering and HA in Proxmox — in the “Virtualisation” reference. Percentiles and load metrics — in the Load testing reference.

Section sources

the section is written from these pages

Backups and disaster recovery

A backup protects against data loss, disaster recovery (DR) — against losing a site or a region. The DR strategy is chosen to match the recovery objectives: RTO and RPO.

A copy is not resilience

High availability survives the failure of a single node, but it does not replace DR: replicas live in the same site or region and share the fate of the primary system. Data deletion and ransomware encryption replicate to the copies just as instantly as ordinary writes — so copies are kept in a separate account and in immutable storage.

A disaster is a different class of event from ordinary failures: it hits many systems at once and takes out the service as a whole. Platform self-healing does not help here — you need a plan.

Recovery objectives: RTO and RPO

RTO (recovery time objective) — the maximum acceptable time between the interruption of a service and its restoration. RPO (recovery point objective) — the maximum acceptable age of data: how many records you can afford to lose. Both objectives are set by the business, not by the infrastructure team.

The numbers come from a business impact analysis (BIA): what a minute of checkout downtime costs and what an hour of lost records costs. For less critical services, an informed decision to go without DR is also an option.

Worked example: RPO of 15 minutes means the transaction log goes to the copy at least once every 15 minutes — anything written later will be lost in a disaster. RTO of 4 hours means the deployment at the standby site, testing included, has to fit into 4 hours.

Where to keep the copies

The basic rule is 3-2-1: three copies of the data, on two different media, one off-site. Veeam extends it to 3-2-1-1-0:

RuleWhat it means
3at least three copies of the data
2the copies on two different media
1one copy off-site
1one copy offline, air-gapped or immutable
0zero errors in a restore verification

The extra “1” covers the scenario where a hacker or a failure deletes both the original and every copy tied to it. Immutable storage with a deletion ban for a set period (object lock) does not yield to this.

The second barrier is access boundaries: the copies live in a separate account with its own permissions. AWS calls this cross-account backup — protection from insider threats and account compromise; object versions help too: a deletion at the source does not erase the copy in the backup storage.

The DR strategies by AWS: backup and restore, pilot light, warm standby, multi-site active-active.

The four DR strategies

AWS lays DR out as four strategies — from copies to two sites serving traffic at the same time:

StrategyWhat runs at the standby siteRTO and RPOCost
Backup and restorenothing: the infrastructure is deployed from backups and IaC codeRTO — up to 24 hours; RPO — hours, depends on how often you back upthe lowest: you pay only for backup storage
Pilot lightdata is replicating, the core of the infrastructure is in place, the servers are offRTO — tens of minutes; RPO — minutesbackup storage plus continuous data replication
Warm standbya scaled-down but running copy of the service, scaled up to full size when neededRTO — minutes; RPO — secondsthe standby runs all the time, but in a reduced form
Multi-site active-activea full copy in two regions, traffic goes to bothRPO — near zero; RTO — potentially zerothe highest: the second site in full

The key difference, by AWS: pilot light serves no requests until the servers are switched on and scaled up, while warm standby already handles traffic, at reduced capacity. If the disaster is the loss of a single data centre at a well-designed, highly available service, backup and restore may be enough; if the disaster is the loss of a whole region, or a regulator demands it, AWS advises looking at pilot light, warm standby or multi-site active-active.

Choosing a strategy

An online shop: RPO of 5 minutes and RTO of 1 hour — losing 5 minutes of orders is unacceptable, and an hour of downtime in the sales season costs too much. Warm standby fits: data replicates continuously, and a scaled-down copy of the service in another region is already running.

Bookkeeping: RPO of 24 hours and RTO of 2 days — a day’s documents can be re-entered, and a day without reports is tolerable. Nightly backups to object storage at another site are enough. Size the backup to the real objectives, not to the maximum: the difference in cost is large.

The DR plan

A strategy is a choice of level, a plan is an executable document. The plan includes: what counts as a disaster and who declares it — at Azure this is a separate role, the DR lead; the order of the failover steps; the plan for communicating with the team and with users; and the criteria and procedure for returning to the primary site (failback).

The communication plan answers three questions: who reports to whom, over which channels, and how often. The criteria for declaring a disaster are written down in advance: without them, in the moment, no one will dare to start the recovery.

Failback is planned just as carefully as the failover: the return is made in a controlled way, after the data has been verified and in a window of low load. The plan has to be reachable during the disaster too: Azure requires keeping it in several formats, including an offline version for printing.

Testing the recovery

An untested copy is a hypothesis. AWS puts it bluntly: the only recovery path that works is the one you test often. DR drills follow a schedule — for example, once a quarter: the copy is restored in a separate environment, the time is measured against the RTO and the data against the RPO.

Next comes chaos engineering: experiments with failures. The steps: define the steady state as a measurable indicator of normal operation; hypothesise that it will hold under a failure; inject real-world events — a server failure, a severed link, a traffic spike; look for a divergence between the control and the experimental group. The blast radius is kept minimal.

Further reading

PostgreSQL backups — the PostgreSQL reference, the section “Backup and restore”; virtual machine copies and Proxmox Backup Server — the section “Backups, snapshots and restore” of the “Virtualisation” reference; RouterOS configuration backups — the section “Backups and export” of the MikroTik reference. Business continuity as a management system (ISO 22301) — the “Standards” section of this reference.

Section sources

the section is written from these pages

Cloud models: IaaS, PaaS and SaaS

Cloud computing, as defined by NIST SP 800-145, is a model in which computing resources are provisioned on demand over a network from a shared pool, and consumption is measured and billed. The difference between IaaS, PaaS and SaaS is which layer of the stack stays with you and which one the provider takes over.

What counts as a cloud

The definition from NIST SP 800-145 has become the accepted one. A cloud is not just any remote server but a service with five essential characteristics:

  • on-demand self-service: a machine or storage is provisioned automatically, without a request to a person at the provider;
  • broad network access: all resources are reached over the network from standard devices and through standard mechanisms;
  • resource pooling: the provider’s capacity is pooled and shared among many customers — which server ended up with whom does not matter;
  • rapid elasticity: resources are allocated and released as needed, sometimes automatically;
  • measured service: consumption is measured and shows up in reports and the bill — you pay for what you used.

The same standard yields three service models and four deployment models.

Service models: IaaS, PaaS and SaaS

The models differ in how much of the stack the provider has taken over: the higher the model, the less work remains for your team — and the less control it has.

ModelWhat the provider deliversWhat stays with youExample
IaaSvirtual machines, disks, virtual networksoperating system, runtimes, applications and dataAzure virtual machines
PaaSa platform for running applications, managed databasesthe application: its code, configuration and dataAzure App Service, Azure SQL Database
SaaSa complete ready-to-use applicationthe users and their work in the applicationMicrosoft 365, Dynamics 365

Choose IaaS when you need control over the system: your own images, your own kernel, your own network rules. Choose PaaS when you want to deal with nothing but code and data. SaaS covers a ready-made task — email, CRM, documents — without in-house development.

Deployment models

A deployment model describes who the cloud is intended for:

ModelWho uses itExample
Publicanyone; the infrastructure sits at the provider’s facilityAWS, Azure, Google Cloud
Privatea single organisation, including its divisions; it can sit on the organisation’s own premises or at the providera company cloud on its own hardware
Communityseveral organisations with shared requirements — for example, on security or compliancea government cloud for public agencies
Hybrida combination of two or more clouds, connected by the movement of data and applicationsa shop’s website in a public cloud, the database with personal data on the organisation’s own premises

Multicloud is not part of this list: it is not a NIST model but a strategy of using several public clouds.

Who is responsible for what

On your own premises you are responsible for the whole stack — from the building to the data. When you move to the cloud, part of the responsibility passes to the provider — the shared responsibility model. Data, configurations, user accounts and client devices stay with the customer under every model; the physical facility, the network, the hosts and virtualisation stay with the provider. The middle layers depend on the chosen model.

On-premises, the whole stack is the customer’s; in the cloud, the provider takes over the lower layers.

The line climbs the stack from left to right: in IaaS the provider takes over virtualisation and everything beneath it, in PaaS it also takes over the runtime and the operating system, and in SaaS only data and access remain with the customer.

Landing zone: the foundation before the first workload

A cloud where workloads are created without preparation quickly turns into a set of disconnected subscriptions. Before the first workload, a landing zone is set up — the term is not translated — as the baseline configuration of the cloud:

  • a hierarchy of subscriptions or accounts;
  • network: internet egress, a connection to the on-premises estate, name resolution;
  • permissions: who is granted access to which subscriptions;
  • logs and monitoring in a centralised store;
  • policies and budgets that constrain the teams.

According to the Azure Cloud Adoption Framework, a landing zone consists of a platform part — a central foundation that sets governance, security and shared resources such as networking and logs — and application landing zones, where teams run workloads within the boundaries set for them.

When hybrid and multicloud are justified

A hybrid cloud, in NIST’s terms, is a combination of two or more cloud infrastructures connected by the movement of data and applications; the most common case is a public cloud plus on-premises infrastructure. Google describes multicloud as an architecture of two or more public providers, sometimes together with a private environment.

  • a phased migration: the application is moved to the cloud in parts while part of it stays at the old site;
  • data that the law requires to stay within the country, with the computing close to it;
  • a backup site: disaster recovery in another cloud or on the organisation’s own premises;
  • avoiding dependence on a single provider: a second cloud as insurance against its prices and outages.

The price is complexity. Google lists among the difficulties of multicloud the growing complexity of management, the integration of software environments, a team with skills across several clouds, and the charge for data transfer between sites.

Edge computing and colocation

Edge computing is computing close to the user or the data source. At AWS this means Local Zones, which bring resources closer to users; Wavelength Zones for services at the edge of mobile operators’ 5G networks; and Outposts, which place AWS services in your own data centre.

Colocation is the opposite of the cloud: your own hardware sits in someone else’s data centre, and you are responsible for everything from the server upwards. The facility owner provides power, cooling, connectivity and access. Details — in the section “Data centers and Tier levels”. A private cloud on your own hardware is covered by the “Virtualisation (KVM, Proxmox)” reference, and data protection and access by the “Security architecture” reference.

Section sources

the section is written from these pages

Network: segmentation, load balancing and CDN

The infrastructure network is designed in segments: a segment is a group of systems with the same access requirements, and traffic between segments passes only through rules. Load balancers sit on top of the segments, a CDN delivers the content, and sites are linked by VPN or dedicated lines.

In the NIST glossary, a demilitarized zone (DMZ) is a segment between the external and internal networks for systems reachable from outside: a server broken into there does not open a path to the rest of the network. Filters on the hosts themselves — in the “Firewall” section of the “Linux server hardening” reference; here — the boundaries.

A typical set of zones for web systems: a public one with load balancers, an application one, data, and management with a bastion and server management interfaces.

The arrows show the direction requests are allowed to take between layers.

VPC and subnets

A virtual private cloud (VPC) is an isolated network in the cloud, inside which you create subnets and rules between them. A public subnet has a route to the internet gateway, a private one does not: it either has no outbound route or only a NAT gateway for outgoing connections. Route tables decide where a packet goes, security groups close the ports.

Plan the address space before the first deployment: VPC ranges must not overlap with the office or other VPCs, otherwise you will never be able to link them later. Google advises keeping networks in custom mode (you set the ranges) and grouping applications into fewer subnets with large ranges: isolation comes from rules, not from splitting into small subnets.

basha VPC in custom mode and NAT for private subnets
gcloud compute networks create prod \    --subnet-mode=customgcloud compute networks subnets create web \    --network=prod \    --range=10.30.0.0/20 \    --region=us-central1gcloud compute routers create prod-router \    --network=prod \    --region=us-central1gcloud compute routers nats create prod-nat \    --router=prod-router \    --region=us-central1 \    --nat-all-subnet-ip-ranges \    --auto-allocate-nat-external-ips

Leaf-spine in the data center

In your own data center and in colocation, the network between racks is built as a Clos topology — leaf-spine: every leaf switch, usually the top-of-rack (ToR) switch, is connected to every spine switch. A path between servers in different racks passes through exactly three switches: leaf — spine — leaf. Equal latency between any two racks is what made large data centers move away from the “access — aggregation — core” tree.

The key figure is oversubscription at the ToR: bandwidth to the servers against bandwidth to the spines. Example: a ToR has 48 ports of 25 Gbit/s to the servers and 6 of 100 Gbit/s to the spines — 1200 Gbit/s down, 600 up, oversubscription 2:1. By the definition in RFC 7938, the topology is non-blocking if there are at least as many uplinks as downlinks (M ≥ N); otherwise it is oversubscribed N/M times.

L4 and L7 load balancers

A load balancer distributes requests between the copies of a service and removes from the pool the nodes that fail the health check: the check waits for a response at a set interval, and after several failures in a row the node stops receiving traffic, returning after a series of successes.

LayerWhat it seesWhat it can doWhen
L4 (TCP, UDP)address and portredirecting connections, preserving the client IPany protocol, high speed
L7 (HTTP)path, headers, cookiesrule-based routing, TLS terminationweb and APIs, a single entry point for services

On L7 the TLS connection terminates at the load balancer: the certificate is kept in one place, and traffic to the nodes travels over the internal network. Re-encryption inside — in the section “TLS and PKI”. On L4 the connection is passed through as is, without parsing the request.

CDN

A content delivery network (CDN) keeps copies of responses on edge nodes closer to the user, and the source server is called the origin. A request goes to the nearest node: popular files it serves itself, the rest it fetches from the origin and caches. This takes off the origin both the load and the outgoing traffic — its most expensive part.

Do not cache personalised responses. By default CloudFront builds the cache key from the domain and the path, but once session cookies are included in it, every unique user gets their own copy of the object in the cache. The lifetime of a response is set by the origin through cache headers: without them an object lives on the edge node for a day.

Linking sites

The office, your own data center and the cloud are linked in two ways. A VPN over the internet (IPsec) is set up in hours and costs only the traffic, but bandwidth and latency depend on the internet. A dedicated line — Direct Connect, Cloud Interconnect or ExpressRoute — is a physical line to the cloud through an exchange point or a provider: traffic does not cross the public internet, latency is stable, while the price is higher and connection takes weeks.

MethodBandwidth and latencyPriceWhen
VPN (IPsec)limited by the internet, latency fluctuateslowdevelopment, the office, a fallback path
A dedicated lineguaranteed bandwidth, stable latencyhigh, port rentalproduction, large volumes of data
Two lines from different carriersthe sum of the linesgrows moderatelyredundancy for any pair of links

For redundancy the rule is simple: a single line is a single point of failure. AWS builds fault tolerance into the connection itself: Site-to-Site VPN keeps two tunnels, each ending in its own AWS availability zone. The dedicated lines AWS Direct Connect and Google Cloud Interconnect offer up to 99.99% — with four connections in two different locations.

Anycast and DNS load balancing

Anycast is one IP address announced from many points of the network: routing itself brings the client to the nearest one. Global load balancers run on it — in Cloud Load Balancing a single anycast address serves backends in all regions — as do DNS servers and CDN nodes. DNS load balancing, where one name resolves to different addresses, and the role of the TTL are covered in the section “DNS: how a name is resolved” of the “TCP/IP and DNS” reference: a short TTL speeds up switching but increases the number of queries.

Further reading

Setting up a load balancer on Nginx — in the section “Load balancing” of the Nginx reference; WireGuard and IPsec on your own router — in the section “VPN” of the MikroTik reference; VLANs between segments — in the section “Interfaces, bridges and VLANs” of the same reference; masks and subnet boundaries — in the section “IPv4: addresses, masks and subnets” of the “TCP/IP and DNS” reference. Microsegmentation and Zero Trust — in the “Security architecture” reference.

Section sources

the section is written from these pages

Compute: servers, VMs and containers

The form of compute is chosen to match the workload: a physical server, a virtual machine (VM), containers or serverless functions offer different degrees of control over the environment and different amounts of upkeep on your side. AWS calls it an anti-pattern to pick the option you are used to and keep growing it instead of changing the form.

The choice is a trade-off: the higher the form stands in the table below, the more of the environment is under your control and the more updating and scaling work falls on you. Amazon EC2 gives you dedicated hardware and a wide choice of instance families, ECS and EKS give easy deployment and identical environments, while Lambda manages the resources for events by itself.

Which option suits which workload

OptionWhen it fitsWhat it costs youHow it scales
Physical serversteady heavy load, special hardware, per-core licencespurchase and depreciation, repairs, spare capacity for failuresslowly: buying and installing a new server
Virtual machinethe typical case: isolated services, different operating systems on the same hardwarethe cost of a hypervisor and its maintenanceby resizing and changing the number of machines in minutes
Containersmicroservices and frequent releases, the same environment at every stagea shared host kernel and orchestration — a scheduler that restarts the failed ones (see the Kubernetes reference for details)by spinning up instances in seconds; the scheduler spreads them across nodes
Serverless functionsshort event handlers, unpredictable trafficcold starts, a limit on execution time, platform lock-inautomatically, from zero to the platform limit

Hyper-converged infrastructure

Hyper-converged infrastructure (HCI) combines compute and storage on the same cluster nodes: HCIHCIhyperconverged infrastructureA platform in which every node carries compute, storage and networking: an ordinary server with disks serves both as a hypervisor and as part of the distributed storage.Read more: HCI removes the separate storage network (SAN). An example is Proxmox VE with Ceph storage directly on the hypervisor nodes: the guide requires at least three identical servers and recommends a network of 10 Gbit/s or faster dedicated to storage traffic.

The downside: compute and storage grow together. To add compute capacity you add a node together with disks, and the other way round. CPU and memory resources for the Ceph services are budgeted in advance: one core or thread for each Ceph service on the node — monitor, manager and OSD — and, per the current recommendation in the guide, at least 8 GiB of memory per OSD.

bashinstalling Ceph on Proxmox VE
pveceph install                # on every node of the clusterpveceph init --network 10.10.10.0/24   # once, on one nodepveceph mon create                     # on every node; three monitors are recommendedpveceph osd create /dev/sdb            # the whole disk, no RAID

How to scale

Vertical scaling (scale up) adds capacity to a single instance, horizontal scaling (scale out) adds instances. Horizontal scaling needs a load balancerload balancerA device or program that distributes incoming requests across several servers so that none is overloaded and the service stays available if some servers fail.Read more: load balancer and an application without state affinity: sessions are kept in external storage, otherwise requests from one client would have to return to the same server.

MethodHowLimitDowntime
Verticalmore CPU and memory for the instancethe largest server availableoften with a resize, that is a restart
Horizontalmore instances behind the load balancerthe number of instances and their costinstances are taken out one at a time, the rest are unaffected

Autoscaling (autoscalingautoscalingA mechanism that automatically adds and removes compute resources — service replicas, cluster nodes or virtual machines — following the load.Read more: autoscaling) ties together three things: limits — a minimum and a maximum number of instances, so that the bill does not come as a surprise; a metric with a threshold; and the time it takes for a new instance to start taking load (warm-up). Azure advises against narrowing the range: if the minimum equals the maximum, scaling will not kick in at all. A threshold below the peak leaves headroom for warm-up, and instances are best added and removed based on the same metric.

Spread the minimum across availability zones: one instance in each, so that losing a zone does not take the service down entirely. Autoscaling is not the cure for databases: their state has to be replicated synchronously, which is a design problem in its own right, not a reaction to a metric.

A worked example

The peak is 2,000 requests per second and one instance handles 400. Dividing gives 5 instances. The service must survive the failure of one of three availability zones: 3 instances per zone, 9 in total. After one zone fails, 6 instances remain — more than the required 5, so the service holds. Two per zone would not be enough: 4 remain — below the required 5, and any one of the zones then becomes a single point of failure (SPOFSPOFsingle point of failureA component of a system whose failure stops the operation of the whole system or its critical part.Read more: SPOF) for the service as a whole.

PlacementTotalAfter a zone failsHolds the peak
2 per zone in three zones64no: 4 out of 5
3 per zone in three zones96yes: 6 out of 5

Managing physical servers

Every server has a management controller — a BMCBMCserver management controllerA dedicated microcontroller on a server’s motherboard that lets you manage the server and monitor its condition even when the main system is not running.Read more: BMC, a separate microcontroller with its own network port: it keeps running while the main system is powered off and handles power, the remote console and sensors. The older IPMI protocol is no longer being developed: in June 2020 its promoters (Dell, HPE, NEC and Intel) announced that there would be no further specification updates and named Redfish from DMTF as the more modern interface.

Redfish is a REST API with JSON over HTTPS for managing a single server and all the devices of a data center. Keep BMC ports in a separate management segment, apart from the network used by the machines: full access to the hardware from the production network is a path to compromising the whole cluster.

bashforced reboot over Redfish
curl -sk -u admin:change-me \  -H "Content-Type: application/json" \  -X POST \  -d '{"ResetType":"ForceRestart"}' \  https://192.0.2.10/redfish/v1/Systems/1/Actions/ComputerSystem.Reset

Section sources

the section is written from these pages

Storage: block, file and object

The way data is accessed determines the kind of storage: blocks — like a disk for the operating system and the database, files — like a shared directory over NFS or SMB, objects — through an S3-compatible HTTP interface. The storage is chosen by how the application reads and writes its data: a wrong choice is not fixed by tuning.

Three kinds of storage

Block storage splits data into addressed blocks: the server sees it as a local disk and lays out the file system itself. File storage organises data into a directory hierarchy and serves it over NFS or SMB — several clients see one directory at once. Object storage keeps every object in the flat namespace of buckets, with a unique identifier and metadata; the application reaches the object over HTTP. In its storage strategy guide, Google advises starting from the requirements: the nature of the data and the load, and whether several clients need access at the same time.

KindAccessTypical dataIn the cloud and in your own data center
blockblocks, like a local diskoperating systems, databases, virtual machine disksEBS, Persistent Disk; LUNs on a SAN
filefiles and directories, NFS or SMBshared directories, a media library for editingEFS, Filestore; NAS
objectobjects over an S3-compatible HTTP APIuser uploads, copies, static assets, archivesS3, Cloud Storage; MinIO, Ceph

SAN, NAS and DAS

NIST SP 800-209 describes the path from direct-attached storage (DAS) — disks inside the server itself — to storage networks. A storage area network (SAN) is a separate network with block access: Fibre Channel, or iSCSI over Ethernet; the server sees its own block volume (a LUN). NAS (network-attached storage) is a file server on the shared network: clients mount a directory over NFS or SMB.

RAID: levels and limits

RAID combines disks into an array for speed or for surviving a disk failure; the data layout is set by the RAID level.

LevelMinimum disksSurvivesUsable capacity
RAID 02nothing: any disk failure loses the arraythe sum of all disks
RAID 12the failure of one diskthe capacity of one disk
RAID 53the failure of one diskthe sum minus one disk
RAID 64the failure of two disksthe sum minus two disks
RAID 104one disk in each mirror pairhalf the sum

While the array is rebuilding, it is degraded — running without redundancy; on a large disk this takes hours. A second failure during that time loses a RAID 5 array in full, and the parity check reads every disk, raising the chance of failure for an already tired disk. On large arrays the safety margin comes from RAID 6 with its second parity.

IOPS, throughput and latency

Three metrics describe storage speed. IOPS is the number of input/output operations per second; throughput is megabytes per second (MiB/s); latency is the time of a single operation. The relation between them: throughput = IOPS × block size — 16,000 IOPS at 16 KiB each gives 250 MiB/s.

In sequential access the bottleneck is throughput: streaming writes, copies, analytics. In random access it is IOPS and latency: databases, virtual machines. The volume type is chosen by the dominant metric: the table of EBS types separates SSD volumes for transactions from HDD volumes for streams.

EBS typeClassIOPS limitLimit, MiB/sWhat for
gp3general purpose SSDup to 80,000up to 2,000databases and virtual machines
io2 Block ExpressSSD with provisioned IOPSup to 256,000up to 4,000workloads with guaranteed IOPS
st1HDD500 (1 MiB operations)up to 500streaming data, logs
sc1HDD250 (1 MiB operations)up to 250rare access, copies
bashon a server with a volume
# monitoring the load on a volumeiostat -dx 5 /dev/nvme0n1 # example outputr/s    w/s     rkB/s  wkB/s    await12.00  850.00  480.00 108800.00 0.45

The iostat readings translate into a decision: 850 writes per second at 108,800 KiB/s — an average block of 128 KiB; await is the average latency. If it grows under a modest load, the volume is switched to a class with guaranteed IOPS.

Storage durability and availability

Storage durability and availability are different quantities: durability answers whether the data is still there, availability — whether the storage answers right now. S3 Standard is designed for 99.999999999% durability of objects per year and 99.99% availability: objects are kept with copies in at least three availability zones, and the service survives the loss of a whole zone. A block volume has humbler figures: EBS gives 99.8–99.9% durability per year for gp3 and HDD volumes and 99.999% for io2 Block Express, but the volume lives in a single availability zone.

Nine nines do not protect against deletion: after a mistaken request S3 will dutifully answer “no such key”. The protection is versioning and off-site copies; planning the copies — the section “Backups and disaster recovery”.

How to choose storage

A project with a database, user uploads and an office file server divides like this:

  • the PostgreSQL database — a block volume with guaranteed IOPS and low latency, for example io2 or gp3 with provisioned IOPS; the database page is 8 KiB, the load is random
  • files uploaded by users — object storage with versioning: S3, Cloud Storage, and in your own data center — MinIO
  • the office shared directories — a NAS over SMB: several clients work with one file system

The sign of a wrong choice is an application emulating the missing layer: thousands of tiny objects instead of a directory, an attempt to mount one block volume on several machines, a database on a file share. Every case is a signal to reread the requirements.

Further reading

Volumes and PersistentVolumes — the Kubernetes reference, the section “Storage: volumes and PersistentVolumes”; mdadm and LVM — the section “Disks and filesystems” of the Linux reference; Ceph and Proxmox storage — the section “Storage and VM disks” of the Virtualisation reference; PostgreSQL copies — the section “Backup and restore” of the PostgreSQL reference.

Section sources

the section is written from these pages

Data centers and Tier levels

A data center is a building or a hall where IT equipment is given power, cooling, network and security. The reliability of the site sets the ceiling of availability for everything standing in it: no service on a Tier I site will be more available than the site itself.

In this section: the rack and its budget, power and cooling, PUE, the Tier levels and the questions to ask a colocation provider. GPU racks and liquid cooling are covered in the “AI infrastructure (GPU)” reference, physical security in the “Security architecture” reference.

The rack and its units

The basic unit of floor space is a server rack, 19 inches wide by the EIA-310 standard. Height is counted in rack units (U): 1U is 1.75 inches, which is 44.45 mm; a typical rack is 42U and holds 42 single-unit devices, or any combination with a smaller total height.

A rack is chosen by its budget — the summary of resources the site grants to each rack; check it against the needs of the equipment before you install anything.

ResourceExample for a typical rack
Units42U, 30U occupied — 12U of headroom for growth
Power5–15 kVA per rack depending on the power configuration
Weightup to 1,360 kg of static load per the rack’s data sheet
Portsuplinks of 1, 10, 40 or 100 Gbit/s

Power: two feeds from the utility input to the PSU

The path of electricity in a data center: the utility input → a UPS (uninterruptible power supply), which carries the load on batteries while the diesel generator starts → a PDU (power distribution unit) in the rack → the server’s two PSUs. The server is connected to two independent feeds, A and B: the failure of one feed, or maintenance on either of them, does not switch the equipment off.

Rack power scheme over two feeds, A and B.

A practical example is an AWS Outposts rack: the power shelf has two inputs, S1 and S2, and three power configurations — 5, 10 and 15 kVA. For a 9.7 kVA load the documentation prescribes the 10 kVA configuration: two inputs on each of the S1 and S2 feeds for redundant single-phase power. The same document sets the hall conditions: a temperature of 5–35 °C and a humidity of 8–80% without condensation.

Cooling: the cold aisle and the hot aisle

A server draws cold air at the front and exhausts hot air at the back. Rack rows are arranged with their front walls facing each other — this is the cold aisle; the back walls form the hot one. Air conditioners supply cold air into the cold aisle, and the hot air escapes upwards. One flipped rack, or one extra fan, breaks the flow for the whole row.

An empty unit is not a minor detail: without a blanking panel, hot air from the back wall is sucked back into the intake of the neighbouring server. Blanking panels go into every free unit immediately after racking.

Cooling is planned together with power: an Outposts rack needs an airflow of at least 145.8 cubic feet per minute (CFM) per kVA — a 10 kVA rack requires about 1,460 CFM.

The energy efficiency of a site is measured by PUE (power usage effectiveness) under ISO/IEC 30134-2: all the energy of the site is divided by the energy of the IT equipment. The IT load draws 500 kW, the whole site 750 kW, so PUE is 1.5: for every kilowatt of computing there is half a kilowatt on cooling and losses. A value of 1.0 is an unattainable ideal: cooling and power transfer always consume something.

The Tier levels

Uptime Institute classifies sites into four Tiers by the criteria of power capacity, redundancy and fault tolerance. The levels are progressive — each one includes the requirements of the lower ones — but this is not a better–worse scale: Tier IV is not better than Tier II, it is built for a different task.

TierWhat it isMaintenance without shutdownEquipment failure
Ibasic capacity: UPS, cooling and generator without redundancyno, a full shutdown for workprotects only against staff mistakes
IIredundant capacity and cooling componentspartly, by taking a component out of servicestops the IT load
IIIseveral distribution paths, one activeyes, concurrently maintainablestops the IT load
IVseveral isolated systems, fault toleranceyes, for any componentdoes not stop the IT load; the risk grows during the work

Choose the level by the requirements of the service, not by prestige: the redundancy that idles in Tier II is paid for twice in Tier IV — building and maintaining independent systems. Uptime Institute is the only organisation that grants Tier certification; it also assesses operations (Operational Sustainability): the processes and practices without which even a Tier IV topology does not save a site from maintenance mistakes.

The ANSI/TIA-942-C standard

ANSI/TIA-942-C is a data center infrastructure standard from the Telecommunications Industry Association: requirements for cabling systems, spaces, power and cooling for sites of any size — enterprise and multi-tenant. This is a different family of documents from the Tiers: a different body and its own certification with four levels of reliability. Check the certificate of a particular site in the registry of the issuing organisation.

Colocation: what is rented and what to ask

In colocation you rent not servers but conditions: separate units, a whole rack, a cage of several racks, or a hall. Power in kilowatts and connectivity to carriers are bought separately. The boundary of responsibility runs at the socket and the port: the provider is responsible for power up to the PDU, cooling and connectivity, and you — for everything standing in the rack.

Before signing the contract, check with the provider:

  • the Tier level and the site’s certificate number in the certification registry
  • the SLA for power and cooling: which outages are compensated and how an outage is counted
  • the “remote hands” service: what it covers, the response time and the price per hour
  • the procedure for hall access: by request, or around the clock without notice
  • which carriers are brought into the building and whether there is a lock-in to one of them

Inside the rack, order is kept by the same budget: a layout by unit, the power draw and weight of every device. Automating the assembly of such racks is covered in the section “IaC, GitOps and deployment strategies”.

Section sources

the section is written from these pages

IaC, GitOps and deployment strategies

Infrastructure as code (IaCIaCInfrastructure as CodeAn approach where servers, networks and cloud resources are described in files, as program code, and managed through version control and automation.Read more: IaC) describes servers, networks and cloud resources as files in a repository, and every change reaches production only through the pipeline. Manual edits in the console create configuration driftconfiguration driftDivergence between the actual state of infrastructure and what its description or code records: manual tweaks, emergency changes and forgotten updates accumulate over time.Read more: configuration drift — a divergence between the environment and the code.

In recommendation OE:05, Azure advises a standard IaC approach with code review and quality checks, and prefers declarative tools. Next come GitOpsGitOpsAn approach to infrastructure management in which a Git repository serves as the source of truth for the desired state, and an agent automatically brings the system to that state.Read more: GitOps, environments and secrets; the second half of the section is about deploying changes safely: release strategies and feature flagsfeature flagA mechanism for switching application features on and off on the fly — by changing a configuration value, without a new build or deployment.Read more: feature flag.

The pipeline runs checks and builds (CI/CDCI/CDcontinuous integration and continuous deliveryA practice in which every code change is built and verified by tests automatically and reaches release through one and the same pipeline.Read more: CI/CD) and applies changes from the same files. Pipeline syntax, secrets and environments are covered in detail in the CI/CD reference.

Declarative or imperative approach

Declarative tools describe the final state of an environment and rely on the system to work out how to bring it to that state; imperative tools list the steps to get there. Azure considers the declarative approach better: the files are simpler and easier to review, while imperative scripts accumulate technical debt over time.

ApproachWhat it describesExamples
Declarativedesired state: which resources should exist and with which propertiesTerraform and OpenTofu, CloudFormation, Kubernetes manifests
Imperativesteps: what to run and in which orderbash and PowerShell scripts, some Ansible tasks

Individual steps are needed with the declarative approach too: templates configure virtual machines or place files. For that, configuration management tools come in — for example, Ansible: playbooks and roles are covered in the Ansible reference, sections “Playbooks” and “Roles and collections”. The Terraform language, HCL, is covered in the Terraform reference, section “The HCL language”.

Immutable infrastructure and drift

Immutable infrastructureimmutable infrastructureAn approach in which servers are never modified after deployment: any change is built into a new image, and the old instance is replaced outright.Read more: immutable infrastructure forbids editing a running server: on every deployment, new instances are brought up from fresh images and the old ones are replaced. Azure contrasts this with mutable infrastructure, where a deployment edits the configuration in place.

Configuration drift is found by comparing the state against the code. Terraform shows the differences in terraform plan, and with -detailed-exitcode it returns exit code 0 when there are no changes and 2 when there are: a value that works for a scheduled check. Azure adds a continuity rule: changes happen only through code and the pipeline — then the risk of drift is lower.

bashpipeline job
# CI: drift fails the job because the exit code is 2terraform plan -detailed-exitcode \  -var-file=prod.tfvars

GitOps

GitOpsGitOpsAn approach to infrastructure management in which a Git repository serves as the source of truth for the desired state, and an agent automatically brings the system to that state.Read more: GitOps gathers the items above into a process. Under the OpenGitOps v1.0.0 principles, the desired state is described declaratively and kept in a repository with full history, without edits on top. An agent pulls the state from the store itself and continuously brings the system towards it.

  • Declarative: the state is described as files.
  • Versioned and immutable: a change is a new commit.
  • Pull-based: the agent reads the store itself.
  • Continuous reconciliation: the agent brings the actual and desired state together.

The agent role is filled by Argo CD and Flux: they run inside the Kubernetes cluster and apply manifests from the repository. The difference between pull and push is easy to see on the diagram: in both cases the change goes through the repository, and what differs is who triggers the deployment.

Push and pull deployment models.

The four OpenGitOps principles are about the state, not the tools; an agent such as Argo CD or Flux is chosen to fit the environment. The mechanics of a Deployment — for example, the maxSurge and maxUnavailable fields — are described in the Kubernetes reference, section “Deploying updates and rolling back”.

Environments and artefacts

The same code deploys to the dev, staging and production environments with different parameters — resource sizes, domains, limits. Azure advises keeping the same IaC files for all environments and telling them apart by parameters rather than by copies of the files.

An artefact is the built, immutable output of the pipeline: a container image, a package, an archive. It is built once and versioned. An artefact repositoryartifact repositoryA server-side store where a team keeps build outputs under permanent versions: libraries, packages and container images.Read more: artifact repository keeps it for all environments; promotion means deploying the same image to staging and then to production, not rebuilding it: two builds from the same commit can come out different.

Environments receive credentials in different ways: the test database password is not the production password, and it must not arrive from production. The rules for issuing secrets in the pipeline are in the CI/CD reference, section “Secrets, variables and OIDC”.

Secrets management

Secrets managementsecrets managementThe discipline and tools for securely storing and issuing sensitive data: passwords, API tokens, encryption keys and certificates.Read more: secrets management decides where passwords, tokens and certificates live, and who reads them and when. OWASP advises centralising storage, issuing, auditing and rotation: secrets do not sit in a repository, in plain text in state or in logs.

  • Secrets vault: a secrets manager — HashiCorp Vault, or the cloud AWS Secrets Manager and Azure Key Vault.
  • Role-based access: minimal rights per secret, not “everyone gets everything”.
  • Rotation: regular replacement, automated where possible.
  • Short-lived credentials: dynamic secrets with a short lease, then revocation.

Short-lived credentials reduce the damage of a leak: a stolen password only lives until the end of its lease. OWASP gives a template: for an application in Kubernetes, a sidecar agent requests secrets from the vault and places them into a shared in-memory volume, refreshing them before they expire. Restarting the application does not revoke the secret by itself: it lives until the vault revokes it or the lease expires.

Leaks are hunted down by scanning repositories and logs: Azure advises scanning IaC repositories for keys and secrets, and OWASP advises building rules on pipeline logs that catch secrets being exported. The topic as a whole is covered in the “Security architecture” reference.

DevSecOpsDevSecOpsThe practice of embedding security into the development and operations pipeline: checks of code, dependencies and infrastructure run continuously and, wherever possible, automatically, rather than as a single check at the end.Read more: DevSecOps in one sentence: security checks are built into the pipeline — dependency and secrets scanning, IaC checks — instead of a manual audit before release.

Deployment strategies

A deployment strategy defines how a new version replaces the old one in production. AWS describes five approaches (rolling update is a variant of an in-place deployment); their cost is time and resources, and rollback is the chance of quickly returning to the previous version.

StrategyHowRollbackCost
In-placethe old version is stopped and the new one is installed on the same resourceby deploying the previous version againminimal, but availability can dip
Rollingin-place, one or a few nodes at a timecontinue back across the nodesthe load balancer takes a node out while it updates
Blue-greentwo full environments, traffic switches to the new oneswitch traffic backdouble resources for the duration of the release
Canarya small share of traffic goes to the new version, then it widensreturn the share to the old versiontwo versions in parallel, plus metrics for the decision
Lineartraffic shifts in equal portions at equal intervalsreturn the share to the old versiona long deployment, two versions in parallel
All at onceall traffic moves to the new version in a single stepa full rollbackno availability guarantee: any defect is seen by everyone

The choice depends on the situation: internal tools get by with in-place or rolling. For customer traffic, blue-green is chosen for a full rollback in one switch, and canary when the new behaviour needs to be checked against metrics. In a Kubernetes cluster, canary is handled by the orchestrator — see the Kubernetes reference, section “Deploying updates and rolling back”.

Feature flags

A feature flagfeature flagA mechanism for switching application features on and off on the fly — by changing a configuration value, without a new build or deployment.Read more: feature flag is a condition evaluated at runtime that switches a feature on or off without a new code deployment. OpenFeature describes gradual rollout to a share of users without restarts or builds — like a canary, only inside the application. The flag decision takes the request context into account: user, address, environment.

pythonevaluating a flag in application code
# the flag decision on a value issued by the OpenFeature SDKnew_checkout = client.get_boolean_value(    "new-checkout", default_value=False,    evaluation_context=ctx,)if new_checkout:    render_new_checkout(order)else:    render_old_checkout(order)

Flag releases need a flag service: OpenFeature is an API and SDK standard that plugs into different systems through providers. Flags are code too, and code ages: once a feature is fully switched on, the flag is removed.

In more detail: IaC at the Terraform level — in the Terraform reference; configuration management — in the Ansible reference; checks and builds in the pipeline — in the CI/CD reference.

Section sources

the section is written from these pages

Observability and operations

Observability is the ability to understand a system’s state from the outside, from its signals, without knowing in advance what exactly will break. There are three signals: metrics, logs and traces. Signals answer the question of whether the system works for its users; alerts, on-call duty and incident reviews turn that answer into action.

Signals do not collect themselves: the application has to be instrumented — the code emits the telemetry itself, and OpenTelemetry is the open standard through which it is collected. Signals are used to set SLO targets (see the section “Availability, SLAs and SLOs”) and alerts on error budget burn.

SignalWhat question it answersExamples
MetricHow much and how fast: how the system behaves over a periodrequests per second, error rate, p99 latency, CPU load
LogWhat happened: events with timestampsa database connection error, a login record
TraceWhere in the chain of services time is losta request: gateway → service → database, each step — a span

Signals and APM

On its own, a log says little: without context you cannot tell which request it belongs to. In a distributed system a request passes through several services. Distributed tracing shows where it slowed down. A trace is the path of a single request from start to finish; a span is one segment of that path, such as a database call.

Application performance monitoring (APM) is an agent in the application plus dashboards of latency and errors per endpoint; traces give it the detail.

OpenTelemetry

OpenTelemetry is an open standard for collecting telemetry. The application gets an API and an SDK: the SDK emits metrics, logs and traces over the OTLP protocol (OpenTelemetry Protocol). The data is received by the Collector — a separate service that processes and exports telemetry. The backend can be anything: Prometheus, Grafana or cloud services. The Collector is usually deployed next to the service: the application offloads data to it quickly, while the Collector handles retries, batching and filtering of sensitive data. To try things out, data can also be sent straight to the backend.

Changing the backend does not change the application instrumentation.

Alerts on the error budget

The SLO target comes from the section “Availability, SLAs and SLOs”, and the error budget is the share of failed requests allowed over a period. For an SLO of 99.9% over 30 days the budget is 43 minutes of full downtime, or the same total of failed responses. An alert should say that the budget is being spent too fast, not that CPU load is high: high load can happen without any harm to users.

The rate of spending is the burn rate: how many times faster the budget is being used up than planned. With a constant error rate of 0.1% over 30 days the budget runs out exactly on time — that is a burn rate of 1. A workable scheme is an alert on two windows: a long one of 1 hour and a short one of 5 minutes with a threshold of 14.4. The long window is responsible for accuracy: the alert means that 2% of the budget has been spent. The short one — that errors are happening right now; after they stop, the alert clears after 5 minutes, not after an hour. The recipe comes from the “Alerting on SLOs” chapter of the SRE Workbook.

yamlalert rule, SLO 99.9% over 30 days
groups:  - name: slo-errors    rules:      - alert: SLOBudgetBurnFast        expr: |          (            job:slo_errors_per_request:ratio_rate1h{job="myjob"}              > (14.4 * 0.001)          )          and          (            job:slo_errors_per_request:ratio_rate5m{job="myjob"}              > (14.4 * 0.001)          )        labels:          severity: page

On-call duty and the runbook

On-call duty is a rotation in which one engineer takes the alerts and a second one backs them up. The load is kept within limits: at Google, on-call duty takes up no more than a quarter of an engineer’s time. There are no more than two incidents per 12-hour shift: reviewing one takes about 6 hours. On an ordinary day there are no pages at all; if the same component triggers pages every day, there are more incidents than the allowed limit, and the load has to be reduced. Notifications escalate: if the on-call engineer does not take the page, it goes to the next one.

For a known alert, a runbook (or playbook) is written — a step-by-step guide: what this alert means, what to check, which actions are safe. An alert without a runbook leaves the on-call engineer a puzzle at three in the morning.

Blameless postmortems

A postmortem is written after a significant failure: visible degradation, data loss, intervention by the on-call engineer. A postmortem is not a punishment but a document for the whole team; the search is for system causes, not for the guilty — that is the principle of the blameless postmortem. The document covers: the impact on users and on the business, a timeline of events, causes and actions with owners and deadlines. A review without actions with dates will reproduce the incident.

DORA metrics

The DORA metrics measure the speed and stability of delivery — five indicators from dora.dev:

MetricWhat it measures
Change lead timefrom a commit in version control to reaching production
Deployment frequencyhow many deployments over a period
Failed deployment recovery timehow long it takes to return to a working state after a failed deployment
Change fail ratewhat share of deployments requires immediate intervention
Deployment rework ratewhat share of deployments — rework after a failure

The five DORA metrics are read in pairs: the first three — delivery throughput, the last two — its instability. MTTR from the former “four keys” has been replaced by the failed deployment recovery time; no targets are set on the metrics — they are used to see movement.

Further reading

SRE (site reliability engineering) is a Google approach in which reliability is an engineering task: SLOs, the error budget and a limit on manual work. Half of the team’s time remains for engineering projects. Recording rules, Alertmanager and dashboards — in the sections “PromQL query language”, “Alerting rules and Alertmanager” and “Grafana dashboards” of the Prometheus and Grafana reference. The systemd journal — in the section “The journal and journalctl” of the systemd reference. Latency percentiles — in the section “Metrics: latency, percentiles, RPS” of the Load testing reference.

Section sources

the section is written from these pages

Cost: TCO, CAPEX, OPEX and FinOps

Total cost of ownership (TCO) — the costs of infrastructure over its lifetime, usually 3–5 years: hardware, floor space, electricity, licences, people and downtime. Deployment options are compared by TCO, not by the price of a server or a virtual machine.

CAPEX and OPEX

Buying servers is capital expenditure (CAPEX): the money is spent at once, and the equipment is written off in parts through depreciation. The cloud and rented capacity are operating expenditure (OPEX): you pay for what you use, on a monthly bill. Trading fixed expense for variable expense is one of the six advantages of cloud computing listed by AWS. Instead of a large investment made before the load is known, you pay for the resources consumed. For a manager the difference comes down to one thing: CAPEX needs budget up front, OPEX follows consumption but is harder to forecast.

TCO is used to compare not “your own server versus a VM” but complete scenarios. The price of own hardware must also include a rack, power and cooling, connectivity, administrators’ time, licences and a standby site. For the cloud it is on-demand VMs or VMs discounted for a commitment, plus disks, backups and egress.

A sample TCO calculation over 3 years

A typical workload: 10 virtual machines, a database and a website. The figures are illustrative, in dollars: they show the structure of costs and the point where own hardware catches up with the cloud, not a real price. Real numbers are calculated from your own rates and salaries.

ItemOwn hardware in colocationCloud
Servers and switches, one-off45 0000
Rack, installation, standby site12 0000
Power and cooling, 3 years18 0000
Connectivity and dedicated addresses, 3 years9 0000
VMs: 10 × 4 vCPU, 16 GiB, 3 years092 000
Disks, backups and traffic, 3 years3 00019 000
Licences (OS, DBMS, redundancy)15 00015 000
Administrators: 2.5 FTEs, 3 years60 00030 000
Total over 3 years162 000156 000

By the end of year three the totals have almost evened out — 162,000 against 156,000. Beyond that the balance changes: own hardware costs 35,000 a year, the cloud 52,000. In year four own equipment is cheaper. A spiky load, or one growing severalfold, makes the cloud more attractive; a steady round-the-clock load favours own hardware. The model is recalculated for your own case.

Cloud payment models

The main Amazon EC2 purchasing options are on-demand, Savings Plans, Reserved Instances, Spot and Dedicated Hosts; other providers offer a similar set. On demand you pay per second, with no commitment. A Savings Plan is a fixed dollar amount per hour for 1 or 3 years. A Reserved Instance is a specific configuration in a region for the same term. Spot is spare capacity that the provider can take back. A Dedicated Host is a whole physical server.

ModelCommitmentSavingsRisk
On-demandnonothe highest hourly price
Savings Plansan hourly amount, 1 or 3 yearsnoticeableyou pay for idle time too
Reserved Instancesa configuration in a regionnoticeablechanging the instance family or platform — only with a convertible contract
Spotnothe largestthe instance can be interrupted
Dedicated Hosthost rentallicence savingslow utilisation

A commitment is taken for the stable part of the load — databases and always-on services. Spot is for interruptible work: batch calculations, test runs. The rest runs on demand. A Reserved Instance can be moved to another availability zone, applied region-wide from one zone, or resized within its family; changing the family or platform requires a convertible contract.

Right-sizing

Right-sizing is matching the types and number of resources to the real load. In AWS Well-Architected terms it is an iterative process: the size is chosen from load data or automatically from metrics, and the process is repeated when the load profile changes and new resource types appear. AWS counts an instance as underutilised when peak CPU and memory use stays below 40% over four weeks — these are downsized first. A practical cycle: collect CPU, memory and disk utilisation over a few weeks, pick a size with headroom and repeat regularly.

Dev and staging environments are not needed at night or at weekends: scheduled auto-stop removes about two thirds of their hours.

Egress traffic

How cloud traffic is priced depends on source, destination and volume — COST08-BP01, data transfer modelling, makes this point. Inbound traffic is usually free. Egress to the internet and between regions and availability zones costs money and often turns out more expensive than expected. Typical surprises on the bill are replication between zones and serving files to users.

Model the traffic before launch: where data comes from, where it goes, how much per month, and what each flow adds up to. For users in a single country a CDN cuts egress from the origin: the cache serves most responses itself. The network solutions behind it are covered in the section “Network: segmentation, load balancing and CDN”.

FinOps: three phases

FinOps is the practice of managing cloud spend. The FinOps Foundation runs it as a cycle of three phases. Inform is collecting spend data and allocating it by team and tag, forecasting and calculating unit economics. Optimize is finding options: right sizes, discounts, architecture. Operate is putting them in place: policies, budgets, alerts on deviations. The phases repeat in a loop.

Tags for cost allocation come from IaC (the section “IaC, GitOps and deployment strategies”); observability shows actual utilisation (the section “Observability and operations”).

bashmonth’s spend by the Environment tag
aws ce get-cost-and-usage \    --time-period Start=2026-10-01,End=2026-11-01 \    --granularity MONTHLY \    --metrics "UnblendedCost" \    --group-by Type=TAG,Key=Environment \    --output json

The command retrieves the month’s spend broken down by the value of the Environment tag. For more detail use the AWS Cost and Usage Report (CUR).

Vendor lock-in

Proprietary managed services create vendor lock-in: moving such a system is expensive. A noticeable share of the exit price is egress during the data transfer: the gigabytes that have to be pulled out of the cloud are billed at full rate.

Lock-in is reduced in advance: open data formats and standard interfaces, infrastructure as code, containers instead of platform lock-in. The price is giving up some convenient managed services in favour of ones that have a compatible replacement. For details see the section “Cloud models: IaaS, PaaS and SaaS”.

Section sources

the section is written from these pages

Common mistakes in approach

Most infrastructure failures grow not out of exotic technologies but out of seven recurring mistakes: unverified backups, everything in a single zone, manual changes in production, secrets in a repository, alerts without objectives, unaccounted-for traffic and complexity for its own sake. For each one, there is a recognisable sign and a response.

Backups without a verified restore

A backup exists, but a restore from it has never been performed — or was performed and missed the target time. The Well-Architected Framework counts among its anti-patterns the assumptions that a restore will take less than the target time, that the data in the backup is undamaged and that the backup works at all.

Worked example: a 2 TB database, a 1 Gbit/s link between sites, an RTORTOrecovery time objectiveA disaster recovery objective: the maximum time in which a service must be working again after a disaster — set by the business before an outage happens.Read more: RTO of 2 hours. Moving the data alone takes 16,000 seconds at ideal bandwidth — about 4.5 hours (2 trillion bytes over a 1 Gbit/s link). The RTO is already broken at the copy stage, before deployment and data verification. Either the target is revised or the strategy is changed — for example, by adding a replica at the standby site.

The right way: restores on a schedule, with the time measured against the RTO and the data against the RPORPOrecovery point objectiveA disaster recovery metric: the maximum age of data that may be lost in a failure — set by the business before disaster strikes.Read more: RPO. AWS advises restoring backups into a separate environment, checking that the data is accessible and intact, automating the checks and telling the service owners whenever a target is exceeded. Details — in the section “Backups and disaster recovery”.

Everything in a single zone or data centre

The workload lives in a single availability zone, and the loss of the zone takes the whole service down — AWS lists this design among its anti-patterns and rates the risk level “high”. An outage spreads further than it seems: servers in a single rack, or a database in a single data centre — any such node becomes a SPOFSPOFsingle point of failureA component of a system whose failure stops the operation of the whole system or its critical part.Read more: SPOF.

The right way: at least two zones for a production workload — compute, the database and a load balancer in each; autoscaling and gateways are spread across the zones as well. Check every component: for some managed databases, replication between zones has to be enabled explicitly. Two regions are the next level up, and they call for recovery targets that a single region cannot meet. Details — in the section “Availability, SLAs and SLOs”.

Manual changes in production

Console edits between deployments are configuration drift: the environment diverges from the code and can no longer be reproduced. When an incident strikes there is nothing to roll back, and the test environment no longer matches production, so what was verified in staging breaks in the production environment. AWS counts manual changes and bypassing the pipeline “because it is urgent” among the anti-patterns of deployment automation.

The right way: changes only through IaCIaCInfrastructure as CodeAn approach where servers, networks and cloud resources are described in files, as program code, and managed through version control and automation.Read more: IaC and a pipeline with checks; a hand edit is replaced by a commit. AWS advises the chain “repository — build and tests — automated deployment with rollback” and not to skip any of its steps even in an emergency: a bypass leaves the environment irreproducible. Working with IaC and GitOps — in the section “IaC, GitOps and deployment strategies”.

Secrets in a repository

A key slips into a commit — and stays in the Git history forever, even after the file is deleted: every history rewrite breaks the references to commits, so a rewrite cannot be counted as erasure. OWASP notes that secrets are far too often kept in code in plain text and scattered across configuration files.

The right way: secrets live in a centralised store, not in code and configuration — OWASP calls for centralising the storage and management of secrets. A leaked key is revoked and replaced immediately: OWASP calls for compromised secrets to be revoked safely. A Git history rewrite is no substitute for revocation. Short-lived credentials shorten the lifetime of access with a stolen key. The solution in detail — in the sections “Secrets management” of the “Security architecture” reference and “Secrets, variables and OIDC” of the CI/CD reference.

Monitoring without SLOs

Hundreds of alerts on CPU and disk utilisation, yet users learn about the outage before the on-call engineer does: the thresholds were guessed, and the signal of real degradation drowns in the noise. An alert on a resource does not answer the main question — whether the service works.

The right way: first the target — an SLOSLOservice level objectiveA quantitative target for a service quality indicator — the share of successful requests, latency, data freshness — that a team maintains over a chosen period.Read more: SLO for the share of successful requests — then the error budgeterror budgetHeadroom for falling short of a reliability target: how many failures a service is allowed at a given SLO — usually 100% minus the SLO.Read more: error budget and alerts on how fast it is spent. The on-call engineer gets a page when the budget is melting too fast; CPU utilisation, unrelated to users, is of interest only on a dashboard. Targets, burn rate and the alert recipe — in the section “Observability and operations”.

Unaccounted-for traffic

The charge for outbound traffic and for traffic between zones turns out to be larger than the charge for the servers: out of the habit of designing for one’s own data centre, where traffic between machines is not billed, data transfer in the cloud is left out of the calculations — AWS calls this a typical case and rates the risk “high”.

Worked example: the database replicates into each of two neighbouring zones at 300 GiB a day — 18,000 GiB a month for replication alone, and every application response to the cache and to users adds its own outbound stream. The traffic model is built before launch: where the data comes from, where it goes and how much of it there is — and architecture options are compared against it. A worked example with figures — in the section “Cost: TCO, CAPEX, OPEX and FinOps”.

Overcomplication

Kubernetes, multicloud and active-active across two regions land on an internal service with a hundred users and a 99% SLO — 7.2 hours of allowed downtime a month. Running such a setup takes up the team that could have been developing the product, and the failure of any link is still sorted out by hand.

The right way: start from the requirements and the simplest design that meets them — the Azure RE:01 checklist explicitly asks to avoid unnecessary complexity. Extra complexity is earned with measurements: an availability target that a single region with two zones can meet does not call for a second region; separate recovery requirements are already grounds for a replica. The requirements an architecture grows out of — in the section “What is infrastructure architecture”.

MistakeSignWhat to do
Backups without verificationa restore has never been performed or missed the RTOrestores on a schedule with the time and the data measured
Everything in a single zonethe loss of a zone or a data centre takes the whole service downat least two zones for compute, the database and the load balancer
Manual edits in productionthe environment diverges from the code and there is nothing to roll back tochanges only through IaC and a pipeline with checks
Secrets in a repositorythe key can be found in the Git history even after the file is deleteda secrets store, immediate revocation and rotation of the key
Alerts without SLOshundreds of pages about CPU, while it is users rather than the on-call engineer who notice the outagean SLO target, an error budget and alerts on how fast it is spent
Unaccounted-for trafficthe traffic bill is larger than the server billa traffic model before launch: sources, destinations, volumes
Overcomplicationclusters and two regions for a service with a 99% SLOthe simplest design that meets the requirements; complicate further only on measurements

Section sources

the section is written from these pages

Standards, frameworks and their status

There is no single standard for infrastructure architecture. Workloads are reviewed against the cloud providers’ Well-Architected frameworks, the facility against Tier levels and ANSI/TIA-942, business continuity against ISO 22301. Energy efficiency is measured by ISO/IEC 30134-2, and the very word “cloud” is defined by NIST SP 800-145. Statuses were checked on 7 November 2026.

Which documents are in force

For the cloud frameworks, the status is shown by the change page: for AWS it is the revision log, for Azure and Google Cloud an updates feed. ISO standards live by the catalogue stages: 60.60 — published, 90.92 — to be revised.

DocumentWhat it definesStatusWhat replaces or supplements it
AWS Well-Architected Frameworkprinciples and questionnaires for reviewing a cloud workloadin force; the last major update was on 6 November 2024six pillars, including sustainability
Azure Well-Architected Frameworkprinciples and questionnaires for reviewing a cloud workloadin force, updated continuouslyfive pillars, Design review checklists and the What’s new feed
Google Cloud Well-Architected Frameworkprinciples and questionnaires for reviewing a cloud workloadin force, updated continuouslysix pillars and industry perspectives
NIST SP 800-145the definition of the cloud: five characteristics, three service models, four deployment modelsin force, September 2011—
Uptime Institute Tier Classification SystemTier levels of facilities, Tier I–IVin forceoperations are assessed by the separate Tier Standard: Operational Sustainability
ANSI/TIA-942-Cdata center infrastructure: cabling, spaces, power, coolingin forceAddendum 1 on AI is in preparation, due in mid-2027
ISO 22301:2019a business continuity management systemin force, under revisionsupplemented by Amd 1:2024; ISO/CD 22301 is in preparation
ISO/IEC 30134-2:2026the PUE energy efficiency metricsecond edition, January 2026it replaced the 2016 edition with its 2018 amendment
OpenGitOps: GitOps Principlesthe four GitOps principlesv1.0.0—
FinOps Frameworkthe phases of cost management: Inform, Optimise, Operatein force—
DORA metrics (software delivery performance metrics)the speed and stability of delivery: five metricsin forcethey replaced the DORA “four keys”
DMTF Redfish (DSP0266)a REST API for managing servers and data centers1.25.0, Redfish release 2026.2it took over from IPMI
The law of the Republic of Uzbekistan “On personal data” (ZRU-547)the rules for processing and storing personal datain forceArticle 27¹ was amended by law ZRU-1125 of 26 March 2026

The Well-Architected pillars at the three providers

The frameworks describe the same job, but each provider has its own set of pillars. At AWS and Azure the performance pillar is called performance efficiency, at Google Cloud it is simply performance. On top of the pillars, Google Cloud adds perspectives — cross-cutting guidance for technologies and industries, for example AI and ML.

PillarAWSAzureGoogle Cloud
operational excellenceyesyesyes
securityyesyesyes
reliabilityyesyesyes
performanceyesyesyes
costyesyesyes
sustainabilityyes—yes

What has changed in the recent editions

  • AWS Well-Architected Framework — the 6 November 2024 revision: the guidance of five pillars was updated — reliability, security, operational excellence, sustainability and performance efficiency; reliability was reworked the most.
  • The Google Cloud Well-Architected Framework is updated continuously: the latest entry on the What’s new page is dated 3 November 2026.
  • ISO/IEC 30134-2:2026 — the second edition of the PUE metric: guidance for mixed-use buildings, refined measurements, accounting for unaccounted energy and on-site generation.
  • ISO 22301:2019 was supplemented by Amd 1:2024 (climate-related changes) and is under revision: ISO/CD 22301 is in preparation.
  • The DORA metrics moved from four keys to five: MTTR was replaced by time to restore service after a failed deployment; the rate of rework after a failure (deployment rework rate) was added.
  • Article 27¹ of the law of the Republic of Uzbekistan “On personal data” is in force in the wording of ZRU-1125 of 26 March 2026. Biometric and genetic data, and the data of telecom subscribers, must be localised.
  • Addendum 1 on AI workloads is in preparation for ANSI/TIA-942-C: high-density cabling, liquid cooling; it is expected in mid-2027.

Outdated documents still cited

  • ISO/IEC 30134-2:2016 and its 2018 amendment have been withdrawn: PUE is calculated under the 2026 edition.
  • TIA-942-B has been superseded by ANSI/TIA-942-C: articles written before 2026 still carry the old letter.
  • IPMI is no longer developed: its promoters (Dell, HPE, NEC, Intel) announced in June 2020 that there would be no further specification updates and named Redfish as the replacement.
  • The DORA “four keys” with the MTTR metric are outdated: the processes are described by five metrics.

Further reading

How the Tier levels and PUE are applied — see the section “Data centers and Tier levels”. GitOps principles and rollout strategies — in the section “IaC, GitOps and deployment strategies”. FinOps phases — in the section “Cost: TCO, CAPEX, OPEX and FinOps”; the five DORA metrics — in the section “Observability and operations”. Business continuity as a process — in the section “Backups and disaster recovery”.

Section sources

the section is written from these pages

End of the reference

What changed

revision history · 5 entries

Every edit is saved as a revision: a snapshot of the reference, the reason and a summary of changes. The published version changes only after the same checks as at creation.

  1. Manual edit

    reason: manual edit
  2. Manual edit

    reason: manual edit
  3. Manual edit

    reason: manual edit
  4. Manual edit

    reason: manual edit
  5. Reference updated

Weekly check

How the reference is checked

Once a week — and right after news of a release or a vulnerability — the reference is checked in three steps.

  1. 1. Freshness

    Sections are compared with the release notes and changelogs from the official sources and with the topic’s news.

  2. 2. Errors

    Every section is read again: wrong facts, outdated APIs and flags, broken examples.

  3. 3. Links — by an HTTP request

    Every source link must respond. A broken link is a reason to recheck the section.

No findings — only the date changes. Findings — only the affected sections are rewritten, and they appear in “What changed”. A new version replaces the published one only after passing the same checks as at creation.

Statuses

Verified
no findings
Updated
sections rewritten, edits are listed
Rechecking
while the check runs, the previous version stays open
Needs review
disputed points: the verified version is shown, editors review

Last check

18 Nov · Check · updated · no findings