A BMC is a small computer inside the server, with its own processor, memory and network port. It runs independently of the main OS and CPU: it can switch the server on and off and show sensors and a console even when the system has hung or is completely powered off. Each vendor has its own name for it: iDRAC from Dell, iLO from HPE, XClarity Controller from Lenovo.
What a BMC is for and what it can do
- Switch the server on and off and force a restart over the network.
- Show sensor readings: temperature, voltage, fan speed and power supply status.
- Keep an event log — for example, overheating or a disk failure.
- Provide a text or graphical console in the browser — even the BIOS boot screen is visible.
- Attach an installation image over the network and install an OS on bare metal.
- Update firmware: the BIOS, the BMC itself, network cards and disk controllers.
How it is built and how it is used
Usually it is a separate chip on the motherboard: a modest processor, a little memory of its own and its own firmware, which runs for as long as the server has power. Sensors from the board report to the BMC, and the BMC is linked to the management bus; in servers with a graphical console, Aspeed chips combine the BMC with a simple GPU for capturing the screen image. For many years IPMI was the standard management interface, and Redfish is now taking its place — a REST API from the DMTF consortium: in 2020 the promoters of IPMI announced that no further updates to the specification were planned and named Redfish as an example of a more modern interface.
curl -k -u admin:password -X POST \ https://bmc-01.example.com/redfish/v1/Systems/1/Actions/ComputerSystem.Reset \ -H 'Content-Type: application/json' \ -d '{"ResetType": "On"}'Why a separate network is needed
A BMC is always reachable over the network — that is both its strength and its risk. The management port lives in a separate, segmented network, unreachable from user networks and from the internet: there are known cases where vulnerabilities in BMC firmware were used to bypass protection; the NIST recommendations on platform firmware resiliency (SP 800-193) apply to BMCs as well. In data centres such a management network is a standard part of the infrastructure, alongside the application network and the storage network.